LineCalc Components
Components and Parameters
Components and Associated Parameters lists the LineCalc-supported
components and any associated parameters that can be modified or
calculated. Components are grouped by substrates and details regarding
their electrical and physical values, references, and other computed
results are given.
Components and Associated Parameters
Component
|
Electrical Parameters
|
Physical Parameters
|
Substrate Parameters
|
Calculated Values
|
COAX
|
Z0 E_Eff
|
Di Do L
|
Er TanD Rho Sigma
|
A_DB
|
RWG
|
Z0 E_Eff
|
A B L
|
Er Rho TanD Mur TanM Sigma
|
K_Eff A_DB
|
Components using the CPWSUB substrate (CPWSUB = * )
|
CPW
|
Z0 E_Eff
|
W G L
|
Er Mur H Hu T Cond TanD Rough
|
K_Eff A_DB SkinDepth |
CPWCPL2
|
ZE ZO Z0 C_DB E_EffComponents using the SSUB substrate (SSUB = * )
|
W G S L
|
Er Mur H Hu T Cond TanD Rough |
KE KO AE_DB AO_DB SkinDepth
|
CPWCPL4
|
ZE ZO Z0 C_DB E_Eff |
W = Wi G S = Si L
|
Er Mur H Hu T Cond TanD Rough |
K_Eff KE KO AE_DB AO_DB SkinDepth
|
CPWG |
Z0 E_Eff |
W G L |
Er Mur H Hu T Cond TanD Rough |
K_Eff A_DB SkinDepth
|
Components using the FSUB substrate (FSUB = * )
|
BFINL
|
Z0 E_Eff |
D L |
Er Cond Fa Fb Fdw |
K_Eff A_DB SkinDepth |
IFINL |
Z0 E_Eff |
D L |
Er Cond Fa Fb Fdw |
K_Eff A_DB SkinDepth |
UFINL
|
Z0 E_Eff |
D L |
Er Cond Fa Fb Fdw |
K_Eff A_DB SkinDepth
|
Components using the MSUB substrate (MSUB = * )
|
MCLIN
|
ZE ZO Z0 C_DB E_Eff |
W S L
|
Er Mur H Hu T Cond TanD Rough |
KE KO AE_DB AO_DB SkinDepth |
MLANG
|
ZE ZO Z0 C_DB E_Eff |
W S L
|
Er Mur H Hu T Cond TanD Rough |
KE KO AE_DB AO_DB SkinDepth |
MLANG6
|
ZE ZO Z0 C_DB E_Eff |
W S L |
Er Mur H Hu T Cond TanD Rough |
KE KO AE_DB AO_DB SkinDepth |
MLANG8
|
ZE ZO Z0 C_DB E_Eff |
W S L |
Er Mur H Hu T Cond TanD Rough |
KE KO AE_DB AO_DB SkinDepth |
MLIN |
Z0 E_Eff |
W L |
Er Mur H Hu T Cond TanD Rough |
K_Eff A_DB SkinDepth |
Components using the SSUB substrate (SSUB = * )
|
SBCLIN |
ZE ZO Z0 C_DB E_Eff |
W S L |
Er Mur B T Cond TanD |
AE_DB AO_DB SkinDepth |
SCLIN |
ZE ZO Z0 C_DB E_Eff |
W S L |
Er Mur B T Cond TanD |
AE_DB AO_DB SkinDepth |
SLIN |
Z0 E_Eff |
W L |
Er Mur B T Cond TanD |
A_DB SkinDepth
|
SLINO |
Z0 E_Eff |
W S L |
Er Mur B S T Cond TanD |
A_DB SkinDepth |
SOCLIN |
ZE ZO Z0 C_DB E_Eff |
W WO S L |
Er Mur B T Cond TanD |
AE_DB AO_DB SkinDepth |
Components using the SSSUB substrate (SSSUB = * )
|
SSCLIN
|
ZE ZO Z0 C_DB E_Eff
|
W S L |
Er Mur H Hu Hl T Cond TanD Rough
|
KE KO AE_DB AO_DB SkinDepth |
SSLIN |
Z0 E_Eff |
W L |
Er Mur H Hu Hl T Cond TanD Rough |
K_Eff A_DB SkinDepth |
References/Shared Parameters
References/Shared Parameters lists the LineCalc-supported references/shared parameters.
References/Shared Parameters
References/Shared Parameters
|
Parameters
|
Parmeter Name
|
Default Value
|
CPWSUB
|
Er H T Cond Rough TanD Hu Mur COND |
10.0 25.0 0.150 4.1e7 0.0 0.0 3.9e+07 mil 1.0 Cond |
FSUB
|
Er Fdw Fa Fb Cond |
2.2 62.5 mil 900.0 mil 400.0 mil 5.8e7 |
MSUB |
Er H T Cond Cond1 Cond2 Rough TanD Hu Mur Diel1 Diel2 Hole Res |
9.6 10 mil 0.150 4.1e7 Cond Cond1 0.0 0.0 3.9e+34m 1.0 Diel Diel1 hole resi |
SSSUB |
Er H T Cond Rough HU HL TanD Mur COND |
10.0 25.0 0.150 4.1e7 0.0 100.0 100.0 0.0 1.0 Cond |
SSUB |
Er B T Cond Cond1 Cond2 TanD Mur |
2.5 62.5 0.150 5.8e7 Cond Con1 0.0 1.0 |
Note: The default MSUB Cond value has changed to be 4.1e7 (the conductivity of gold).
|
Parameter Definitions
Parameter |
Definition |
A |
Width of rectangular waveguide |
A_DB |
Total attenuation of the structure in dB |
AE_DB |
Total even mode attenuation of coupled section in dB |
AO_DB |
Total odd mode attenuation of coupled section in dB |
B |
Ground plane spacing from top to bottom (stripline) or height of rectangular waveguide |
C_DB |
Coupling factor in dB, i.e., C(dB) = 20log10 [(ZE-ZO)/(ZE+ZO)] |
D |
Gap width in length units |
DI |
Inner diameter (COAX) |
DO |
Outer diameter (COAX) |
E |
Electrical length of line or coupled section (angle units) |
E_EFF |
Effective electrical length of line or coupled section (angle units) |
E_MEAN |
Mean electrical length of coupled microstrip or coplanar waveguide section (angle units) |
ER |
Substrate relative dielectric constant |
G |
Gap between conductor and ground planes (CPW, CPWG) |
H |
Substrate thickness in length units |
HL |
Lower ground plane to substrate spacing in length units |
HU |
Upper ground plane to substrate spacing in length units |
HC |
Distance from top cover to top of substrate in length units |
KE |
Even-mode effective dielectric constant: KE=[C/Vp(even mode)]2 |
K_EFF |
Effective dielectric constant: K_EFF=(C/Vp)2 |
KO |
Odd-mode effective dielectric constant: KO=[C/Vp(odd mode)]2 |
L |
Length of line or coupled section |
MUR |
Relative permeability |
Rough |
RMS surface roughness in length units |
S |
Spacing between lines |
SI |
Spacing between inner center conductors (CPWCPL4) |
SIGM |
Dielectric conductivity value in Siemens per meter |
T |
Metal thickness |
TAND |
Dielectric loss tangent |
TANM |
Magnetic loss tangent |
TEMP |
Temperature; can not be modified by the user |
W |
Width of line |
WI |
Width of inner center conductors (CPWCPL4) |
WO |
Offset of coupled lines for offset coupled stripline |
Ze |
Impedance for even-mode |
Zo |
Impedance for odd-mode |
Z0 |
For coupled-line components, such as SCLIN or MCLIN, Z0=sqrt(Ze × Zo) |
Changing Parameter Defaults
The default parameters that appear in the LineCalc window for editing are set in a file called
lcuiinit in the directory
$HPEESOF_DIR/linecalc/lib (where
$HPEESOF_DIR
represents the complete path for your installation). You can make a
local copy of this file and change the default parameters so that less
editing is required whenever you use LineCalc.
To modify the
lcuiinit file:
- Copy the file lcuiinit to a directory of your choosing. Using any text editor, make the desired changes. Save the file.
- Now you need to tell the program where to look for your customized file. Make a local copy of the LineCalc configuration file linecalc.cfg found in $HPEESOF_DIR/config. Copy this file to $HOME/hpeesof/config.
- Using any text editor, locate the variable LCALCUI_INIT_FILE and modify the path to point to the location of your modified lcuiinit file.
| Note On the PC, $HOME represents the path you specified as the Home Folder during installation ( C:\users\default by default); $ HPEESOF_DIR represents the path you specified as your Program Folder during installation ( C:\AdvDesSys ). |
The component definition format is:
ELEMENT <element_name> <element_id> <# of ports>
<units> <physical> [<physical_fixed> <physical>]
<subst> <tand> <sigma> <temp>
<electrical>
[<electrical_fixed><electrical>]<result>
For example:
ELEMENT COAX COAX_DEFAULT 4 UNITS PHYSICAL PHYSICAL_FIXED PHYSICAL SUBST ELECTRICAL RESULT UNITS UNITS_DEFAULT
FREQ_VAL=10.00 FREQ=GHz LENGTH=mil RES=ohm ANGLE=deg
PHYSICAL DI=37.00
PHYSICAL_FIXED DO=90.00
PHYSICAL L=650.00
SUBST COAXSUB=COAXSUB_DEFAULT ER=2.10 TAND=0.0003 RHO=1.0
ELECTRICAL Z0=35.00 E=90.00
RESULT A_DB=0.01
0 comments: